ODH2-3IA

Commercial / Residential grade GU10 base 3" Line Voltage Air-Tight Recessed Housing


Description:
  • Adjustable hangar bar from 14"-24"
  • Thermally protected with shut off sensor
  • New construction & 3″ Line Voltage Insulated
  • Wire through junction box & rated for damp locations
  • Meets State of WA energy code ASTM E283 for Air Tight
Lamp Type GU10 base 50W Max
Input Voltage 120V AC
Output Voltage 120V AC
Mounting Four-sided
Application Commercial / Residential
Included Push-in connectors
Cover to protect exposed cone from paint

Air-Tight Installation

  1. Hanger Bars:
    Insert bar hangers into the slots on the plaster frame.
    Position bar hangers so that nail in tabs point away from housing or point down to ceiling
  2. Fastening Fixture to Ceiling:
    Joist-type ceilings — Extend hanger bars to fit between joists.
    Position fixture temporarily by hammering "nail-in" tabs into joists then secure permanently with nails.
    Hangers should be level with bottom of joists.
    Suspended (T-bar) Ceilings — Extend hanger bars 1" past T-bars then rest fixture on T-bars.
    Secure fixture to T-bars with wire
  3. Electical Connection:
    Junction box contains two wires:
    Black (live +) and a white (neutral -) which must be spliced to the house current feed wires.
    Make sure to splice WHITE to WHITE and coloured or BLACK to BLACK.
    After splicing has been completed, tuck splices carefully into junction box and replace cover


Grounding

  • For Romex or 3 wire Bx, flexible Armour cable installations
    attach supply ground lead (green) to bars copper ground lead or
    ground screw in wiring box mount or mounted on plaster frame

Proud Partners