HET06-R

Commercial grade Preset In-wall Countdown Single Pole Timer


Description:
  • Neutral wire is required
  • ON/OFF Button with hold on function
  • Works with most common lighting types
  • Replaces standard lights or fan single pole switches
  • 6 time selection buttons with activation indicator lights
  • Ideal for closet, pantry, garage, laundry room, outdoor lighting and spa
Voltage 125V AC /60Hz
Resistive 15A
Ballast 1200VA
Tungsten 1000W
Electronic Ballast/LED 5A or 600W
Motor 1/2 HP
Time Delay 5 min / 10 min / 30 min / 60 min / 2 or 4 hours
Rating Commercial Indoor use only
Humidity 95% RH, non-condensing
Operating Temperature 0°C to +55°C

Wire the Timer Switch
 

  • Twist the existing wires together with the wire leads on the timer switch.
    Cap them securely using the wire nuts provided
  • Connect the green or non-insulated (copper) GROUND wire from the circuit to the GROUND wire on the HET06-R
  • Connect the power wire from the circuit (HOT) to the black wire on the HET06-R
  • Connect the power wire to the lamp or fan (LOAD) to the red wire on the HET06-R
  • Connect the NEUTRAL wires from the circuit (NEUTRAL) to the white wire on the HET06-R
  • Please check the presence of neutral wire, and DO NOT connect neutral with load wire together