Next Generation Universal Series Fan (Contractor Pack For Fan Housing And Fan Motor Assembly)
Air Volume (CFM) | 50 |
Static Pressure (in inches w.g.) | 0.1 |
Noise (sones) | 3.4 |
Fan Watts | 44.2W |
Duct Diameter | 3" |
Power Rating | 120V /60Hz |
Housing Size | 7-1/2"×7-1/4"×3-5/8" |
Grille Dimensions | 8-3/4"×9-1/2" |
Warranty | 1 year |
Case Quantities | 8 |
Assembly Instructions
MOUNT DIRECTLY TO JOIST OR I-JOIST
Place the housing assembly in the opening so the bottom edge is
flush with the finished ceiling. Nail the housing assembly to the joist
using nails.
POSITION THE HOUSING ASSEMBLY
Position the housing assembly against the joist. With a pencil, trace
an outline of the housing assembly onto the ceiling. Set the housing
aside, and cut out an opening for the fan.
GRILLE INSTALLATION
Press the springs on the grille together, and insert the springs into
the motor plate inside the housing assembly. Firmly push the grille
up against the ceiling.