Energy Recovery Ventilator with efficient cross-flow core
Accessories (sold separately):
ODD-ERV-TIMER | FAP (Flush Access Panel) | MAD (Mud Access Panel) | PAV-B (Polymetric Air Valve) | SAV (Supply Air Valve) |
Heating | Net Outdoor Airflow | Sensible Recovery Efficiency | Adjusted Sensible Recovery Efficiency | Apparent Sensible Effectiveness | Average Power | Net Moisture Transfer |
i | 67.8 CFM | 76.7% | 80.1% | 82.2% | 32W | 0.63 |
ii | 97.2 CFM | 70.6% | 74.3% | 76.7% | 52W | 0.55 |
iii | 107 CFM | 69.3% | 73.4% | 75.4% | 66W | 0.53 |
Cooling | Net Outdoor Airflow | Sensible Recovery Efficiency | Adjusted Sensible Recovery Efficiency | Apparent Sensible Effectiveness | Average Power | Net Moisture Transfer |
i | 66.1 CFM | 65.9% | 72.2% | 76.9% | 32W | 0.64 |
Selecting Installation Site
Mechanical Installation (Ceiling Mount)
To mount the unit to the ceiling, use belts rigidly fixed to a horizontal surface or threaded rods and expansion anchors.
The belt, threaded rods and expansion anchors are not included in the delivery set.