OT-24200-TDWJ

Maximum 200W class 2 LED Driver available in 24V DC output


Description:
  • Cooling by free air convection
  • High efficiency: up to 86% & Min.Load 10% only
  • Full protection aluminum housing for dry / damp locations
  • Match with TRIAC, electronic low voltage, magnetic low voltage dimmers
  • PWM output (Pulse-Width Modulation) output, does not change the colour index
  • Flicker-free, compatible with Forward phase, Reverse phase, TRIAC, MLV, ELV Dimmers
  • Work for 110-277V AC input, 120V & 277V dimmers, allows for flicker free dimming down to 1%
Input Voltage 110-277V AC
Output Voltage 24V DC
Maximum Wattage 200W
Amps 8.33A
Dimmable Yes
Frequency Range 47-63Hz
Power Factor 0.98 at 120V AC
0.95 at 277V AC
Efficiency (Typ.) 86%
AC Current (Max.) 2.3A at 110V AC
Short Circuit Shut down o/p voltage;
Repower on to recover after fault condition is removed
Over Loading 120%
Operating Temperature -40ºC ~ +60ºC
Operating Humidity 20-90% RH, non-condensing
Safety Standards UL 8750
Withstand Voltage I/P-O/P: 1880V AC
Isolation Resistance I/P-O/P: 100MΩ / 500V DC / +25ºC / 70% RH
Warranty 5 years
Case Quantities 10

 

How to Connect Driver Cord to Fixed Wiring

  1. Please check and make sure orientation of output and input sides of driver are correct for installation
  2. Phase dimmer / TRIAC dimmer is connected with input of LED Driver to get dimming.
    (Forward phase, Reverse phase, Magnetic Low Voltage, and Electronic Low Voltage and TRIAC dimmers are okay)
  3. Input BLACK (L) and WHITE (N) wires to be connected to AC,
    GREEN wire to be connected to GROUND.
    Output RED and BLACK wires to be connected to LED lighting
  4. On the output side, the RED wire is positive (+) and the BLACK is negative (-).
    If the polarity is reversed, the LED fixture will not work. (+) and (-) will be shown on the label
  5. For indoor and outdoor, dry / damp location use
  6. The LED Driver is not to be repaired and DO NOT use any longer if it is damaged or defective
  7. The LED Driver does not reply upon the luminaire enclosure for protection against accidental contact with live parts
  8. DO NOT overload